Question: Write a C program to run on ocelot which will flip a single bit in a number entered by the user using the binary representation of the number. The user should input the original integer value between 1 and 1000 inclusive using a scanf. – Free Chegg Question Answer
| | |

Question: Write a C program to run on ocelot which will flip a single bit in a number entered by the user using the binary representation of the number. The user should input the original integer value between 1 and 1000 inclusive using a scanf. – Free Chegg Question Answer

Write a C program to run on ocelot which will…

Question: Please record your answer to the following true or false questions. Explain in detail and not just mention true or false a. (5 points) True or False: Circuit switched networks do not suffer from queueing delay. b. (5 points) True or False: Packet switching is used in computer networks because it is cheaper. c. (5 points) True or False: POP3 is an example of “request-n-reply” application layer protocol. 2. DNS (15 points total. Approx. 20 minutes) a. (5 points) In your own words, briefly describe the key function of the Internet Domain Name System (DNS). (One or two sentences should suffice.) – Free Chegg Question Answer
| |

Question: Please record your answer to the following true or false questions. Explain in detail and not just mention true or false a. (5 points) True or False: Circuit switched networks do not suffer from queueing delay. b. (5 points) True or False: Packet switching is used in computer networks because it is cheaper. c. (5 points) True or False: POP3 is an example of “request-n-reply” application layer protocol. 2. DNS (15 points total. Approx. 20 minutes) a. (5 points) In your own words, briefly describe the key function of the Internet Domain Name System (DNS). (One or two sentences should suffice.) – Free Chegg Question Answer

Transcribed text From Image: Please record your answer to the…

Question: A parallel flow heat exchanger has its tubes of 5 cm internal and 6 cm external diameter. The air flows inside the tubes and receives heat from hot gases circulated in the annular space of the tube at the rate of 100 kW. Inside and outside heat transfer coefficients are 250 W/ m2K and 400 W/ m2K respectively. Inlet temperature of hot gases is 500 °C; outlet temperature of hot gases is 300 °C, inlet temperature of air 50°C, Exit temperature of air 140 °C. Calculate: i) Overall heat transfer coefficient based on outer surface area ii) Length of the tube required to affect the heat transfer rates. Neglect the thermal resistance of the tube. iii) If each tube is 3 m length find the number of tubes required.  – Free Chegg Question Answer
| |

Question: A parallel flow heat exchanger has its tubes of 5 cm internal and 6 cm external diameter. The air flows inside the tubes and receives heat from hot gases circulated in the annular space of the tube at the rate of 100 kW. Inside and outside heat transfer coefficients are 250 W/ m2K and 400 W/ m2K respectively. Inlet temperature of hot gases is 500 °C; outlet temperature of hot gases is 300 °C, inlet temperature of air 50°C, Exit temperature of air 140 °C. Calculate: i) Overall heat transfer coefficient based on outer surface area ii) Length of the tube required to affect the heat transfer rates. Neglect the thermal resistance of the tube. iii) If each tube is 3 m length find the number of tubes required. – Free Chegg Question Answer

Transcribed text From Image: A parallel flow heat exchanger has…

Question: 4-1) A 5 KVA 200/1000 V, 50 Hz single-phase transformer gave the follow test results: V2 0.C. test (L.V.S: 200V, 1.2 A, and 90 w. S.C. test (H.V.S: 50V, 5 A, and 110 w. Using the transformer as step-up transformer to delivering 3 KW at a power factor of 0.8 lagging. I. Calculate the parameters of the equivalent circuit referred to low voltage – Free Chegg Question Answer
| |

Question: 4-1) A 5 KVA 200/1000 V, 50 Hz single-phase transformer gave the follow test results: V2 0.C. test (L.V.S: 200V, 1.2 A, and 90 w. S.C. test (H.V.S: 50V, 5 A, and 110 w. Using the transformer as step-up transformer to delivering 3 KW at a power factor of 0.8 lagging. I. Calculate the parameters of the equivalent circuit referred to low voltage – Free Chegg Question Answer

Transcribed text From Image: 4-1) A 5 KVA 200/1000 V,…